Two Ear Flywheel Housing (Requied by NFPA)
To make sure engine maintain good condition, in NFPA20 standard required to start up the engine with NO FLOW, which mainly to rotate the engine to protect the crankshaft and camshaft of engine to aviod the harms from the same position for too long time. But too often start of engine with idle speed, will caused the trouble on the fuel system, which the nozzles can have carbon fouling due to low speed running.
As part of SinoMac, PumpMac provides abundant premium pump-driven power pack options, WPT PTO, Advance gearbox and pump head, as well as customized water pump set. We also have a set of NFPA20 standard engine power pack accessories including air intake shut-off valve, DC contactor, engine control panel, jacket water heater etc. We provide full life cycle services for all customers, from design to power system supply, from installation to commissioning, from after-sales service training to spare parts supply, from trouble shooting to overhaul technical support.
If you are in need of pump model that not available on our website for the moment, please contact SinoMac sales team for technical details and related documents, our well trained sales and engineering team will help you with all products and techical documents available here at UL-listed.com.

Two-ear Flywheel Housing
To achieve this function, we have solution of add A4: Two-ear Flywheel Housing and A5: Spring Starter Motor to be able to rotate the engine flywheel manually, then you don’t have to start up the engine weekly, just need to start up the engine monthly to make sure engine under good condition of starting in case of on fire.

Spring Starter Motor
When you manually rotate the engine, the crankshaft and camshaft changed postion already, which comply the purpose of NFPA20 standard already. Meanwhile, due to don’t have to start engine weekly, can help end-user to lower down operation costs (Saving fuel costs) and lower down the emissions of fire pump set, also it’s a third starting system just in case that two sets of batteries are flat, engine still able to start up without using any batteries. Read More
Over Speed Protection Device
This list including all Series of NFPA20 Components.
Click here to find pump engines by type (Fuel System & Engine Speed).
Spring Starter Motor
Spring Starter Motor (Required by NFPA) Spring Starter Motor — Provides rotational energy for diesel engine starting. Pure mechanical energy storage concentrates released human-generated energy to propel the engine to starting speed.Power Loss Control Unit— Provides...
Cardan Shaft
Cardan Shaft (Required by NFPA) The cross-type cardan shaft utilizes its structural characteristics to enable two shafts that are not on the same axis, have a large angular misalignment, or have significant axial movement to operate continuously at constant angular...
Spark Arrester
Spark Arrester (Requied by NFPA) After long-term use of the engine, a large number of carbon particles accumulated in the exhaust pipe fall off and encounter high temperature gas, which will burn and produce sparks flying out of the exhaust pipe. If there is...
Diesel Engine Fire Pump Drivers
PumpMac Diesel Engine Fire Pump Drivers Diesel Engine Fire Pump Drivers are composed of diesel engine controller SY-DEC-F010, water pump coordination module SY-WPC-F090, information display module SY-DCP-F070 and other relevant command switches and buttons. They are...
Emergency Engine Stop Device
Emergency Engine Stop Device (Requied by NFPA) The fire pump emergency engine stop device is the last line of defense for fire safety, and its practical application cases cover three core dimensions: equipment protection, personnel safety, and system reliability. From...
Fire Engine Monitor
Fire Engine Monitor (Requied by NFPA) When the fire-fighting pump system need to work, the environment might have lot of smoke which make it difficult for rescue team to read anything, so NFPA20 standard have clearly requirement on the easy access of engine running...
VSPLC Start Up Device
VSPLC Start Up Device (REQUIRED by NFPA with engine higher than 200kW) Due to the pump drive engine always start engine with water pump connected, which have large torque on the engine, so NFPA20 have clearly requirement for VSPLC start up device of the engine higher...
Water Heater
Water Heater (Requied by NFPA) To make sure engine start up very fast at any working environment, have to make sure the coolant water keep at a reasonable temperature, its required to maintain water temperature at 49 degrees (+-5 degrees), So we have to add the A7:...
Over Speed Protection Device
Over Speed Protection Device (Requied by NFPA) Due to the engine overspeed can caused huge damages to engine itself, sometimes the parts inside of engine can be damaged and break out from engine block, can caused people injured. So NFPA20 standard have clearly...
Engine Starting System
Engine Strating System (Requied by NFPA) When the automatic control circuit fails and the storage battery of the main circuit and the starting motor are in good condition, Battery Contactors can be used to start the diesel engine fire pump mechanically (directly...