Spring Starter Motor (Required by NFPA) Spring Starter Motor — Provides rotational energy for diesel engine starting. Pure mechanical energy storage concentrates released human-generated energy to propel the engine to starting speed.Power Loss Control Unit— Provides...
NFPA Engine Accessories
PumpMac NFPA20 Engine Accessories has the NFPA Certified components including the engine starting system, optional components, over speed protection device, water heater, VSPLC…, and PumpMac’s Fire Water Pump Control Box-FPEC100. This series can be quickly integrated with various firefighting pumps (including UL-certified pumps) and put into operation without additional modifications, significantly shortening the project deployment cycle and reducing system adaptation costs. Additionally, relying on its “ready-to-use” compliance, it becomes an efficient choice for general contractors of firefighting projects in scenarios such as fire acceptance inspections and emergency drills.
SinoMac is a partner of PumpMac for many years, we are a professional pump system solution supplier with many years of experience. We provide customers from all over the world with one-stop pump system solutions from pump system design to pump system supply, from installation to commissioning, and from after-sales. Providing sales service support for spare parts supply, SinoMac is your reliable pump system partner, providing you with the best value for money and reliable system solutions.
Advantages of NFPA Engine Accessories
NFPA 20 Full Compliance: Designed strictly in line with NFPA 20 (2013 Edition) standards, integrated with UL-listed fire-fighting engines and compliant components, ensuring smooth passing of fire acceptance and meeting the requirements of cross-border and high-end fire projects.
Pre-integrated Efficient Deployment: All core parts (engine, control system, dual batteries, coolant heater, etc.) are pre-assembled and debugged at the factory. It can be put into use immediately after on-site connection, reducing deployment time by over 50% compared with separate assembly.
Broad Compatibility: Adopts standardized interface design, which is seamlessly compatible with various types of fire pumps (centrifugal, axial flow, etc.) and control panels, adapting to different project scales and pump power requirements.
Find Pump Engines by Series
This is the list of all series of NFPA20 Engine Accessories.
Click here to find components by type (Fuel System & Engine Speed).
Cardan Shaft
Cardan Shaft (Required by NFPA) The cross-type cardan shaft utilizes its structural characteristics to enable two shafts that are not on the same axis, have a large angular misalignment, or have significant axial movement to operate continuously at constant angular...
Spark Arrester
Spark Arrester (Requied by NFPA) After long-term use of the engine, a large number of carbon particles accumulated in the exhaust pipe fall off and encounter high temperature gas, which will burn and produce sparks flying out of the exhaust pipe. If there is...
Diesel Engine Fire Pump Drivers
PumpMac Diesel Engine Fire Pump Drivers Diesel Engine Fire Pump Drivers are composed of diesel engine controller SY-DEC-F010, water pump coordination module SY-WPC-F090, information display module SY-DCP-F070 and other relevant command switches and buttons. They are...
Emergency Engine Stop Device
Emergency Engine Stop Device (Requied by NFPA) The fire pump emergency engine stop device is the last line of defense for fire safety, and its practical application cases cover three core dimensions: equipment protection, personnel safety, and system reliability. From...
Fire Engine Monitor
Fire Engine Monitor (Requied by NFPA) When the fire-fighting pump system need to work, the environment might have lot of smoke which make it difficult for rescue team to read anything, so NFPA20 standard have clearly requirement on the easy access of engine running...
VSPLC Start Up Device
VSPLC Start Up Device (REQUIRED by NFPA with engine higher than 200kW) Due to the pump drive engine always start engine with water pump connected, which have large torque on the engine, so NFPA20 have clearly requirement for VSPLC start up device of the engine higher...
Water Heater
Water Heater (Requied by NFPA) To make sure engine start up very fast at any working environment, have to make sure the coolant water keep at a reasonable temperature, its required to maintain water temperature at 49 degrees (+-5 degrees), So we have to add the A7:...
Over Speed Protection Device
Over Speed Protection Device (Requied by NFPA) Due to the engine overspeed can caused huge damages to engine itself, sometimes the parts inside of engine can be damaged and break out from engine block, can caused people injured. So NFPA20 standard have clearly...
Two-ear Flywheel Housing
Two Ear Flywheel Housing (Requied by NFPA) To make sure engine maintain good condition, in NFPA20 standard required to start up the engine with NO FLOW, which mainly to rotate the engine to protect the crankshaft and camshaft of engine to aviod the harms from the same...
Engine Starting System
Engine Strating System (Requied by NFPA) When the automatic control circuit fails and the storage battery of the main circuit and the starting motor are in good condition, Battery Contactors can be used to start the diesel engine fire pump mechanically (directly...